Rev. F 3-26-04 17 P/N 520050
WATER TEMPERATURE SENSOR
For use with optional Indoor Control Panel only.
Select a convenient location to mount the Temperature Sensor (model TS-5L) in the plumbing system between
the filter pump and the heater.
Drill a 5/16” diameter hole in the pipe, and insert the Sensor.
Use a screwdriver to open the hose clamp (included). Position clamp over the Sensor, and gently tighten around
the pipe.
CAUTION
Overtightening of clamp can cause deformation of o-ring seal.
Run 2-conductor cable (25 ft. is included with Installation Hardware package) between Sensor location and
low-voltage compartment of LX-100 RF Power/Load Center.
At the LX-100 RF Power/Load Center, strip insulation of both conductors ¼”, and connect to circuit board at
SNS- and SNS+ Screw Terminals. Pay attention color-coding (green conductor connects to SNS-; red conductor
connects to SNS+).
+12
FRZ
AUX1
SPA
GND
SNS+
AUX3
AUX2
SNS-
REMOTE SWITCHES
C
S
P
GHTR
12
WATER TEMPERATURE
SENSOR
LX-100 RF POWER/LOAD CENTER
RED
GRN